Newmar GI-30-FS 30-Amp Fail Safe Galvanic Isolator
Original price was: $194.36.$120.86Current price is: $120.86.
Description
The Newmar GI-30-FS Fail Safe Galvanic Isolator reduces galvanic corrosion caused by low-voltage currents traveling through the shore-power grounding system. Installed between the AC safety ground and the vessel’s DC bonding network, it helps protect underwater metals while preserving the safety-ground connection required for fault protection.
An internal capacitor provides an additional low-impedance path for AC current, while the fail-safe design keeps ground continuity intact if the isolator experiences an internal failure. The unit supports 115V and 230V shore-power installations and is designed to withstand substantial short-circuit current.
The GI-30-FS meets ABYC A-28 fail-safe requirements and carries UL1500 ignition-protection certification. This makes it appropriate for marine installations where both corrosion protection and grounding-system integrity are essential. For boats using 30A shore-power service, the Newmar GI-30-FS provides certified galvanic isolation in a purpose-built fail-safe design. Find more in our battery charging accessories.











